JRT Calibration Services
JRT Calibration Services
610-327-9610

Sentry 8501 System Specifications

ENERGY RESPONSE: Energy Dependent

OPERATING INDICATED USE: Gamma detection between ( 35 KeV – 3.0 MeV )

ISOTOPE ENERGY LIBRARY: On board MCA for energy Identification 99 Gamma isotopes

SENSITIVITY: Typical 15cps/uR/hr 137-Cs gamma

SYSTEM: Windows XP Base Operating System

SAMPLING RATE: 1 milliseconds with high efficiency detector circuitry

SAMPLING RATE for ISOTOPE I.D.: 2 seconds

SCINTILLATOR: 2.0 inch Diameter x 2.0 inch Thick NaI (Tl) crystal

 

SYSTEM CHASSIS: NEMA III Rated Security Enclosure Power Requirements: 110 VAC / 500 Watts (220VAC/250 Watts) Height = 16in, Width = 11in, Depth = 8in, Weight = 14 pounds

DISPLAY MONITOR: 8 inch VGA TFT with touch screen

DISPLAY RESOUTION: 640 x 480 native, supports input scaling of 1280 x 1024

CCD: High End Advanced Technology (H.E.A.T.), Ultra high resolution of 470 lines, light capability of 0.03 lux, or lower Length @ 3.25in, Depth @ 2.0in, Diameter @ 1.75in, Wt. @ 0.3 lbs. Power requirements @ 5.0 Volts @ 150 mA.

STROBE: Water resistant, high intensity Xenon lamp, Flash rate @ ½ second Visibility up to ½ mile. Length @ 2.5in, Depth @ 1.25in, Ht. @ 1.25in Power requirements @ 12 Volts @ 150 mA